Generator
now browsing by category
California Highway Patrol Chico, CA
Jauregui & Culver, Inc. installed a complete fueling system including an Above-Ground Storage Tank, two Wayne dispensers, two FuelMaster pedestals, veeder-root, and more. Also installed was a complete fueling system for a back-up Generator including Above-Ground Storage Tank, Simplex Packaged Pump Set unit, and piping.
BlueSky Emergency Generator Fill System Installation
Jauregui & Culver, Inc. furnished and installed the Pryco Remote Fill Station and piped from the remote fill port to the generator’s belly tank with Brugg double wall stainless steel flexible pipe. The piping was run continuous with no joints. We installed a conduit and wiring from the fill station to the generator belly tank to the tank high/low sensor and wired for the solenoid valve. Jauregui & Culver, Inc. provided all testing and inspections.
Fuel Polishing
When the mass power outage spread through Southern California and parts of Arizona in 2013, those who had generators and other forms of emergency power were ahead of the curve. They were prepared, but was their fuel? If your diesel fuel has been stored or unused for a long period of time, then it is of utmost importance to have it polished.
A clean fuel system is essential for preventative maintenance for your diesel engine. One of the main problems with diesel fuel is contamination from algae, microorganisms, fungus, yeast, and bacteria. Algae survive on the hydrocarbons in the fuel and the oxygen in the water in suspension and in the bottom water. If left untreated, the contamination can cause plugged filters, motor operation problems, and expensive repairs. These preventable symptoms of unclean fuel can and will lead to unnecessary failure of your emergency generator.
Early signs of contamination include but are not limited to:
- Dark, smoky exhaust that persists even after the engine of your generator has warmed up.
- Any discovery of corrosion in the fuel tank, or other metal parts that contact the fuel
- Hard deposits on engine injectors are an early and often subtle indicator. (Normal deposits should wipe clean with a cloth.)
The process is relatively simple. We circulate the fuel through a special filter system which removes particulates and purifies the fuel. We then place an additive into the fuel which kills any remaining algae and aids in keeping the fuel clean. There is a clear distinction between samples taken before and after polishing. Upon request, samples can be analyzed through a lab to provide further verification of these results.
At Jauregui & Culver, Inc., we want to serve you and help prevent the expense and inconvenience of generator failure as a consequence of contaminated fuel. It is recommended that your fuel be polished at least once every two years, though most major oil companies, engine manufacturers, and regulatory bodies recommend polishing yearly for back up power sources. In critical facilities, such as hospitals, fuel should be polished at least twice annually to ensure that it is in pristine condition when it is needed for use.
We’ll clean up your fuel and keep you out of the dark!
For more information, please contact us at (760) 743-0518
LPL San Diego Tower
Jauregui & Culver, Inc. procured permits for and installed a 4,000 gallon Above-ground Storage Tank (AST) for diesel and double wall steel fuel piping. We furnished and installed AST remote fill assembly, fuel filtration unit, fuel management control panel, Duplex pump system, and tank monitoring system, including all low voltage electrical wiring and conduit.
Current Projects
Current Projects
These are just a few of the many projects Jauregui & Culver, Inc. is part of. In addition, we service over 300 different sites throughout California. We offer our customers the very best in safety, quality, and customer service.
Sam’s Club Fullerton, CA ground up station
Gaslamp Hotel San Diego, CA emergency generator install
AST Upgrades Multiple sites. More details can be found here.
Federal, State, City & Municipal
Federal & State Government/City/Municipality Customers
US Navy – Port Hueneme, Oxnard, CA.
Underground Storage Tank (UST) installation, shoring w/high water issues, UST piping and environmental remediation.
US Navy – North Island, San Diego, CA.
Underground Storage Tank removal and Aboveground Tank (AST) installation.
US Navy – San Clemente Island, CA.
Underground Storage Tank removal and Aboveground Tank installation.
US Boarder Patrol – San Diego, CA.
UST re-piping, UST tank top, Under Dispenser Pans and Veeder Root System.
US Boarder Patrol – Tecate, CA.
Re-piping and Boiler repairs.
FAA Western Samoa Islands
Underground Storage Tank upgrades
County of San Diego, CA.
- San Diego Operations- UST installation, piping, demolition, and generator install
City of San Diego, CA.
- Mt. Hope Cemetery Maintenance Facility – UST removal and AST installation
- ESD Operations – Secondary Containment repairs
- Barrett Lake – UST removal and AST installation
- El Capitan Reservoir – UST removal and AST installation
City of Rancho Cucamonga, CA.
UST removal and AST with Dispnser installation
El Cajon USD, CA.
UST removal and AST installation
El Toro Water District, CA.
UST removal and AST installation
City of Murrietta Police Department
AST installation
Indian Reservations
Pala Mini Mart
Re-pipe and dispenser replacement