fuel station construction

now browsing by tag

 
 

Scripps Memorial Hospital

Jauregui & Culver, Inc. furnished and installed three UST’s for the emergency generator and boiler, potable water tank, and septic tank. We put in flex, double wall, steel piping and provided trenching and back-fill.

 

 

 

 

 

Sam’s Club Murrieta #4822

Jauregui & Culver, Inc. provided a turnkey fuel system replacement including tanks, dispensers, piping, monitoring system, Healy Clean Air Separator, and vent assembly. Additionally, we furnished and installed a 10,000 gallon diesel UST to add to the existing fuel system.

 

 

Sam’s Club Vacaville #6433

Jauregui & Culver, Inc. repaired one under dispenser containment (UDC) unit. The UDC was leaking brine liquid. Jauregui & Culver, Inc. excavated next to the UDC and sealed the leak using fiberglass matting and resin per manufacture specifications and industry standards. Once completed, the Veeder Root sensor was reinstalled and tested for functional ability.

 

 

 

 

Fuel Polishing

 

When the mass power outage spread through Southern California and parts of Arizona in 2013, those who had generators and other forms of emergency power were ahead of the curve. They were prepared, but was their fuel?  If your diesel fuel has been stored or unused for a long period of time, then it is of utmost importance to have it polished.

A clean fuel system is essential for preventative maintenance for your diesel engine.  One of the main problems with diesel fuel is contamination from algae, microorganisms, fungus, yeast, and bacteria.  Algae survive on the hydrocarbons in the fuel and the oxygen in the water in suspension and in the bottom water.  If left untreated, the contamination can cause plugged filters, motor operation problems, and expensive repairs.  These preventable symptoms of unclean fuel can and will lead to unnecessary failure of your emergency generator. 

Early signs of contamination include but are not limited to:

  • Dark, smoky exhaust that persists even after the engine of your generator has warmed up.
  • Any discovery of corrosion in the fuel tank, or other metal parts that contact the fuel
  • Hard deposits on engine injectors are an early and often subtle indicator.  (Normal deposits should wipe clean with a cloth.)

The process is relatively simple.  We circulate the fuel through a special filter system which removes particulates and purifies the fuel.  We then place an additive into the fuel which kills any remaining algae and aids in keeping the fuel clean. There is a clear distinction between samples taken before and after polishing.  Upon request, samples can be analyzed through a lab to provide further verification of these results.

 

At Jauregui & Culver, Inc., we want to serve you and help prevent the expense and inconvenience of generator failure as a consequence of contaminated fuel.  It is recommended that your fuel be polished at least once every two years, though most major oil companies, engine manufacturers, and regulatory bodies recommend polishing yearly for back up power sources. In critical facilities, such as hospitals, fuel should be polished at least twice annually to ensure that it is in pristine condition when it is needed for use.

We’ll clean up your fuel and keep you out of the dark!

For more information, please contact us at (760) 743-0518 

COC Fuel Facility

Jauregui & Culver, Inc. did a full design build for the County of San Diego Operation’s fuel facility. We procured permits, installed tanks, canopy, and a fuel system. We custom built the shoring that went in on the sides of the tank hole. The concrete footings, tank slab, and drive slabs were poured. Jauregui & Culver, Inc. also installed the fuel management system and continues to provide service and testing for the station. The existing fuel site was demolished, and can be seen here.

In addition, Jauregui & Culver, Inc. provided piping for the emergency generator system and is continuing to design build for the emergency generator system and other projects at this facility.

 

 

 

 

Sam’s Club Bakersfield #4819

Sam’s Club #4819 Bakersfield was a ground up fuel station. Jauregui & Culver, inc. excavated and installed two 20,000 gallon 87 gasoline and one 20,000 gallon split 12,000/8,000 10′ diameter Xerxes Underground Storage Tanks (UST) and deadmen.

We installed Fiberglass, APT, and steel piping to compile the fueling system, including trenching and gravel backfill. Two 3+1 gas/diesel dispensers and four 3+0 gas dispensers were installed, including the Under Dispenser Containment (UDC) basins, dispenser hanging hardware, and dispenser valance. Brine and vacuum tubing for the Veeder Root continuous monitoring and Pressure and Flow sensors in dispenser for the In Station Diagnostics (ISD). The Healy Clean Air Separator (CAS) was installed as part of the EVR II system.

We provided required Enhanced Leak Detection (ELD) testing of the fuel system at the conclusion of the installation of the fueling system and prior to opening. All fuel lines were purged and the dispensers calibrated, completing this project.

LPL San Diego Tower

Jauregui & Culver, Inc. procured permits for and installed a 4,000 gallon Above-ground Storage Tank (AST) for diesel and double wall steel fuel piping.  We furnished and installed AST remote fill assembly, fuel filtration unit, fuel management control panel, Duplex pump system, and tank monitoring system, including all low voltage electrical wiring and conduit.

 

 

Jet Air Tank Removal

Jauregui & Culver, Inc. removed two single wall 12,000 gallon tanks enclosed in a concrete vault.  Demolition and environmental remediation were provided.

 

 

 

 

 

 

Scripps Memorial Hospital Tank Installation

Watch as our team flawlessly installs this UST at Scripps Memorial Hospital.

 

Pala Mini Mart Dispenser Replacement

Jauregui & Culver, Inc. furnished and installed new dispensers for the Pala Casino Mini Mart. We also fabricated and installed a column style canopy extension which including engineer drawings and structural calculations.